1
V048K096M025

Vicor Corporation
(V048x096x025) Voltage Transformation Module
may be paralleled to deliver hundreds of amps at an output voltage settable from 5.20 to 11.0 Vdc. The VTM V048K096T025’s nominal output voltage is 9.6 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 5.20 to 11.0 Vdc at no load,
Datasheet
2
V048K160M015

Vicor Corporation
(V048x160x015) Voltage Transformation Module
higher power levels at an output voltage settable from 8.67 to 18.3 Vdc. The VTM V048K160T015’s nominal output voltage is 16 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 8.67 to 18.3 Vdc at no load, and from 8.15 to 17.9 Vdc
Datasheet
3
V048K480M006

Vicor Corporation
(V048x480x006) Voltage Transformation Module
r power levels at an output voltage settable from 26.0 to 55.0 Vdc. The VTM V048K480T006’s nominal output voltage is 48 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 26.0 to 55.0 Vdc at no load, and from 24.8 to 53.9 Vdc at ful
Datasheet
4
V048K015T100

Vicor Corporation
(V048x015T100) Voltage Transformation Module
input to output. It achieves a response time of less than 1 µs and delivers up to 100 A in a volume of less than 0.25 in3 while providing low output voltages with unprecedented efficiency. It may be paralleled to deliver hundreds of amps at an outpu
Datasheet
5
V048K096T025

Vicor Corporation
(V048x096x025) Voltage Transformation Module
may be paralleled to deliver hundreds of amps at an output voltage settable from 5.20 to 11.0 Vdc. The VTM V048K096T025’s nominal output voltage is 9.6 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 5.20 to 11.0 Vdc at no load,
Datasheet
6
V048K030T070

Vicor Corporation
(V048x030T070) Voltage Transformation Module
may be paralleled to deliver hundreds of amps at an output voltage settable from 1.63 to 3.43 Vdc. The VTM V048K030T070’s nominal output voltage is 3 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 1.63 to 3.43 Vdc at no load, an
Datasheet
7
V048F040T050

Vicor Corporation
(V048F040x050) Voltage Transformation Module
m a 48 Vdc input Factorized Bus, Vf, and is controllable from 2.17 to 4.58 Vdc at no load, and from 1.98 to 4.40 Vdc at full load, over a Vf input range of 26 to 55 Vdc. It can be operated either open- or closed-loop depending on the output regulatio
Datasheet
8
V048K060M040

Vicor Corporation
(V048x060x040) Voltage Transformation Module
y be paralleled to deliver hundreds of amps at an output voltage settable from 3.25 to 6.87 Vdc. The VTM V048K060T040’s nominal output voltage is 6 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 3.25 to 6.87 Vdc at no load, and
Datasheet
9
V048K120T025

Vicor Corporation
(V048x120x025) Voltage Transformation Module
It may be paralleled to deliver hundreds of amps at an output voltage settable from 6.5 to 13.7 Vdc. The VTM V048K120T025’s nominal output voltage is 12 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 6.5 to 13.7 Vdc at no load,
Datasheet
10
V048F160M015

Vicor Corporation
(V048x160x015) Voltage Transformation Module
higher power levels at an output voltage settable from 8.67 to 18.3 Vdc. The VTM V048K160T015’s nominal output voltage is 16 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 8.67 to 18.3 Vdc at no load, and from 8.15 to 17.9 Vdc
Datasheet
11
V048F160T015

Vicor Corporation
(V048x160x015) Voltage Transformation Module
higher power levels at an output voltage settable from 8.67 to 18.3 Vdc. The VTM V048K160T015’s nominal output voltage is 16 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 8.67 to 18.3 Vdc at no load, and from 8.15 to 17.9 Vdc
Datasheet
12
V048K160T015

Vicor Corporation
(V048x160x015) Voltage Transformation Module
higher power levels at an output voltage settable from 8.67 to 18.3 Vdc. The VTM V048K160T015’s nominal output voltage is 16 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 8.67 to 18.3 Vdc at no load, and from 8.15 to 17.9 Vdc
Datasheet
13
V048K480T006

Vicor Corporation
(V048x480x006) Voltage Transformation Module
r power levels at an output voltage settable from 26.0 to 55.0 Vdc. The VTM V048K480T006’s nominal output voltage is 48 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 26.0 to 55.0 Vdc at no load, and from 24.8 to 53.9 Vdc at ful
Datasheet
14
V048F015T090

Vicor Corporation
(V048x015T090) Voltage Transformation Module
nput to output. It achieves a response time of less than 1 µs and delivers up to 90 A in a volume of less than 0.25 in3 while providing low output voltages with unprecedented efficiency. It may be paralleled to deliver hundreds of amps at an output v
Datasheet
15
V048K015T090

Vicor Corporation
(V048x015T090) Voltage Transformation Module
nput to output. It achieves a response time of less than 1 µs and delivers up to 90 A in a volume of less than 0.25 in3 while providing low output voltages with unprecedented efficiency. It may be paralleled to deliver hundreds of amps at an output v
Datasheet
16
V048F020T080

Vicor Corporation
(V048x020T080) Voltage Transformation Module
Datasheet
17
V048K020T080

Vicor Corporation
(V048x020T080) Voltage Transformation Module
Datasheet
18
V048F030T070

Vicor Corporation
(V048x030T070) Voltage Transformation Module
may be paralleled to deliver hundreds of amps at an output voltage settable from 1.63 to 3.43 Vdc. The VTM V048K030T070’s nominal output voltage is 3 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 1.63 to 3.43 Vdc at no load, an
Datasheet
19
V048F040M050

Vicor Corporation
(V048F040x050) Voltage Transformation Module
m a 48 Vdc input Factorized Bus, Vf, and is controllable from 2.17 to 4.58 Vdc at no load, and from 1.98 to 4.40 Vdc at full load, over a Vf input range of 26 to 55 Vdc. It can be operated either open- or closed-loop depending on the output regulatio
Datasheet
20
V048F060M040

Vicor Corporation
(V048x060x040) Voltage Transformation Module
y be paralleled to deliver hundreds of amps at an output voltage settable from 3.25 to 6.87 Vdc. The VTM V048K060T040’s nominal output voltage is 6 Vdc from a 48 Vdc input Factorized Bus, Vf, and is controllable from 3.25 to 6.87 Vdc at no load, and
Datasheet