Sensitron |
Three-Phase IGBT BRIDGE 4- Under-voltage shutdown is automatically reset once the VCC rises above the 12.1V threshold limit. 5- Desaturation shutdown is a latching feature and internally reset. 6- When any of the internal protection features is activated, SD is pulled down |
|
|
|
Sensitron |
Three-Phase IGBT BRIDGE 4- Under-voltage shutdown is automatically reset after 300 msec once the VCC rises above the threshold limit. 5- Desaturation shutdown is a latching feature and internally reset after 300 msec. 6- When any of the internal protection features is acti |
|
|
|
Sensitron |
Three-Phase IGBT BRIDGE 4- Under-voltage shutdown is automatically reset after 300 msec once the VCC rises above the threshold limit. 5- Desaturation shutdown is a latching feature and internally reset after 300 msec. 6- When any of the internal protection features is acti |
|
|
|
Sensitron |
Three-Phase IGBT BRIDGE TBD DC Bus Voltage Rate of Rise With 15V Supply Removed, dv/dt Junction To Case Thermal Resistance RθJC - - C/W MODULE TOTAL WEIGHT Estimated Total Weight 13 OZ • 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 • |
|
|
|
Sensitron |
Three-Phase IGBT BRIDGE TBD DC Bus Voltage Rate of Rise With 15V Supply Removed, dv/dt Junction To Case Thermal Resistance RθJC - - C/W MODULE TOTAL WEIGHT Estimated Total Weight 13 OZ • 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 |
|
|
|
Sensitron |
Three-Phase IGBT BRIDGE assured safety or by means of users’ fail-safe precautions or other arrangement. 3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of the user’s units according |
|
|
|
Sensitron |
Three-Phase IGBT BRIDGE assured safety or by means of users’ fail-safe precautions or other arrangement. 3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of the user’s units according |
|
|
|
Sensitron |
Three-Phase MOSFET BRIDGE SD can be used to shutdown all IGBTs except the brake IGBT by an external command. An open collector switch shall be used to pull down SD externally. Also, SD can be used as a fault condition output. Low output at SD indicates a latching fault situa |
|
|
|
Sensitron |
Three-Phase MOSFET BRIDGE assured safety or by means of users’ fail-safe precautions or other arrangement. 3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of the user’s units according |
|
|
|
Sensitron |
Three-Phase MOSFET BRIDGE assured safety or by means of users’ fail-safe precautions or other arrangement. 3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of the user’s units according |
|
|
|