logo

Sensitron SPM DataSheet

No. Partie # Fabricant Description Fiche Technique
1
SPM6G060-120D

Sensitron
Three-Phase IGBT BRIDGE
4- Under-voltage shutdown is automatically reset once the VCC rises above the 12.1V threshold limit. 5- Desaturation shutdown is a latching feature and internally reset. 6- When any of the internal protection features is activated, SD is pulled down
Datasheet
2
SPM6G080-060D

Sensitron
Three-Phase IGBT BRIDGE
4- Under-voltage shutdown is automatically reset after 300 msec once the VCC rises above the threshold limit. 5- Desaturation shutdown is a latching feature and internally reset after 300 msec. 6- When any of the internal protection features is acti
Datasheet
3
SPM6G080-120D

Sensitron
Three-Phase IGBT BRIDGE
4- Under-voltage shutdown is automatically reset after 300 msec once the VCC rises above the threshold limit. 5- Desaturation shutdown is a latching feature and internally reset after 300 msec. 6- When any of the internal protection features is acti
Datasheet
4
SPM6G120-120D

Sensitron
Three-Phase IGBT BRIDGE
TBD DC Bus Voltage Rate of Rise With 15V Supply Removed, dv/dt Junction To Case Thermal Resistance RθJC - - C/W MODULE TOTAL WEIGHT Estimated Total Weight 13 OZ
• 221 West Industry Court  Deer Park, NY 11729  (631) 586 7600 FAX (631) 242 9798
Datasheet
5
SPM6G140-060D

Sensitron
Three-Phase IGBT BRIDGE
TBD DC Bus Voltage Rate of Rise With 15V Supply Removed, dv/dt Junction To Case Thermal Resistance RθJC - - C/W MODULE TOTAL WEIGHT Estimated Total Weight 13 OZ
• 221 West Industry Court  Deer Park, NY 11729  (631) 586 7600 FAX (631) 242 9798
Datasheet
6
SPM6G150-060D

Sensitron
Three-Phase IGBT BRIDGE
assured safety or by means of users’ fail-safe precautions or other arrangement. 3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of the user’s units according
Datasheet
7
SPM6G250-120D

Sensitron
Three-Phase IGBT BRIDGE
assured safety or by means of users’ fail-safe precautions or other arrangement. 3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of the user’s units according
Datasheet
8
SPM6M020-060D

Sensitron
Three-Phase MOSFET BRIDGE
SD can be used to shutdown all IGBTs except the brake IGBT by an external command. An open collector switch shall be used to pull down SD externally. Also, SD can be used as a fault condition output. Low output at SD indicates a latching fault situa
Datasheet
9
SPM6M050-010D

Sensitron
Three-Phase MOSFET BRIDGE
assured safety or by means of users’ fail-safe precautions or other arrangement. 3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of the user’s units according
Datasheet
10
SPM6M060-010D

Sensitron
Three-Phase MOSFET BRIDGE
assured safety or by means of users’ fail-safe precautions or other arrangement. 3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during operation of the user’s units according
Datasheet
11
SPM6M070-020D

Sensitron
Three-Phase MOSFET BRIDGE
4- Under-voltage shutdown is automatically reset once the VCC rises above the 12.1V threshold limit. 5- Desaturation shutdown is a latching feature and internally reset. 6- When any of the internal protection features are activated, SD is pulled dow
Datasheet
12
SPM6M080-010D

Sensitron
Three-Phase MOSFET BRIDGE
4- Under-voltage shutdown is automatically reset once the VCC rises above the 12.1V threshold limit. 5- Desaturation shutdown is a latching feature and internally reset. 6- When any of the internal protection features are activated, SD is pulled dow
Datasheet