No. | Partie # | Fabricant | Description | Fiche Technique |
---|---|---|---|---|
|
|
QUANTUM |
QT 11x Series Variations s with QT110 The QT111 sensor is exactly the same in all respects to the QT110 with the following exceptions shown in bold (refer to Table 2-1 in the QT110 datasheet): Table 2-1 Output Mode Strap Options Tie Pin 3 to: DC Out DC Out Toggle Pulse Vdd |
|
|
|
QUANTUM |
10 KEY QTOUCH SENSOR IC - self detects faults z Lower per key cost than many mechanical switches z Lead-free package APPLICATIONS PC peripherals Television controls Instrument panels Appliance controls Pointing devices Gaming machines Actual Size QT1100A charg |
|
|
|
QUANTUM |
Designed to Output raw Data over a Master-mode SPI Port QDO H[KLELWV D ORJDULWKPLF UHVSRQVH )RU HYHU\ GRXEOLQJ RI &[ WKH VLJQDO GHFUHDVHV E\ DSSUR[LPDWHO\ 7KH 63, RXWSXW YDOXH LV QRW FRPSHQVDWHG IRU GULIW 63, &ORFN 7KH 63, FORFN KDV SRVLWLYHJRLQJ FORFN HGJHV WKDW VKRXOG EH XVHG WR FORFN WKH VHU |
|
|
|
Quantum |
8-KEY QTOUCH SENSOR IC as the older device but differs in the following ways: Rs resistors on each channel eliminated Up to 4x more sensitive for a given value of Cs Shorter burst lengths, less power for a given value of Cs ‘Burst B’ only mode for lower key counts |
|
|
|
QUANTUM |
8 KEY QTOUCH SENSOR IC which provide for reliable, trouble-free operation over the life of the product. Burst operation: The device operates in ‘burst mode’. Each key is acquired using a burst of charge-transfer sensing pulses whose count varies depending on the value of t |
|
|
|
QUANTUM |
SENSOR ICs One, toggle mode, permits on/off touch control for example for light switch replacement. Another makes the sensor output a pulse instead of a DC level, which allows the device to 'talk' over the power rail, permitting a simple 2-wire twisted-pair in |
|
|
|
QUANTUM |
10 KEY QTOUCH SENSOR IC which provide for reliable, trouble-free operation over the life of the product. Burst operation: The device operates in ‘burst mode’. Each key is acquired using a burst of charge-transfer sensing pulses whose count varies depending on the value of t |
|
|
|
QUANTUM |
QWHEEL/QSLIDE/QTOUCH IC which provide for reliable, trouble-free operation over the life of the product. In particular the QT1106 features advanced self-calibration, drift compensation, and fast thermal tracking. Unlike prior devices, the QT1106 can tolerate power supply fl |
|
|
|
QUANTUM |
QT 11x Series Variations s with QT110 The QT111 sensor is exactly the same in all respects to the QT110 with the following exceptions shown in bold (refer to Table 2-1 in the QT110 datasheet): Table 2-1 Output Mode Strap Options Tie Pin 3 to: DC Out DC Out Toggle Pulse Vdd |
|
|
|
QUANTUM |
QT 11x Series Variations s with QT110 The QT111 sensor is exactly the same in all respects to the QT110 with the following exceptions shown in bold (refer to Table 2-1 in the QT110 datasheet): Table 2-1 Output Mode Strap Options Tie Pin 3 to: DC Out DC Out Toggle Pulse Vdd |
|
|
|
QUANTUM |
(QT140 / QT150) 4 AND 5 KEY QTOUCH SENSOR ICs can lead to entirely new product concepts, adding high value to product designs. Each of the channels operates independently of the others, and each can be tuned for a unique sensitivity level by simply changing its sample capacitor value. The device |
|
|
|
QUANTUM |
(QT140 / QT150) 4 AND 5 KEY QTOUCH SENSOR ICs can lead to entirely new product concepts, adding high value to product designs. Each of the channels operates independently of the others, and each can be tuned for a unique sensitivity level by simply changing its sample capacitor value. The device |
|
|
|
QUANTUM |
10-KEY SENSOR IC as the older device but differs in the following ways: • Rs resistors on each channel eliminated • Up to 4x more sensitive for a given value of Cs • Shorter burst lengths, less power for a given value of Cs • ‘Burst A and B’ only mode for up to eight |
|
|
|
QUANTUM |
CHARGE-TRANSFER IC and is set to ~60s. This will vary slightly with Cs and if SYNC mode is used. As the internal timebase for Max On-duration is determined by the burst rate, the use of SYNC can cause dramatic changes in this parameter depending on the SYNC pulse spaci |
|
|
|
QUANTUM |
SENSOR ICs One, toggle mode, permits on/off touch control for example for light switch replacement. Another makes the sensor output a pulse instead of a DC level, which allows the device to 'talk' over the power rail, permitting a simple 2-wire twisted-pair in |
|
|
|
QUANTUM |
QT 11x Series Variations s with QT110 The QT111 sensor is exactly the same in all respects to the QT110 with the following exceptions shown in bold (refer to Table 2-1 in the QT110 datasheet): Table 2-1 Output Mode Strap Options Tie Pin 3 to: DC Out DC Out Toggle Pulse Vdd |
|
|
|
QUANTUM |
CHARGE-TRANSFER QLEVEL SENSOR IC is the 'slosh filter', a detection integrator which averages detections over a rolling 15 second interval before activating or deactivating the OUT pins. This filter allows use of the QT114 with violently moving fluids, for example in a moving vehicl |
|