logo

QUANTUM QT1 DataSheet

No. Partie # Fabricant Description Fiche Technique
1
QT111

QUANTUM
QT 11x Series Variations
s with QT110 The QT111 sensor is exactly the same in all respects to the QT110 with the following exceptions shown in bold (refer to Table 2-1 in the QT110 datasheet): Table 2-1 Output Mode Strap Options Tie Pin 3 to: DC Out DC Out Toggle Pulse Vdd
Datasheet
2
QT1100A-ISG

QUANTUM
10 KEY QTOUCH SENSOR IC
- self detects faults z Lower per key cost than many mechanical switches z Lead-free package APPLICATIONS Š PC peripherals Š Television controls Š Instrument panels Š Appliance controls Š Pointing devices Š Gaming machines Actual Size QT1100A charg
Datasheet
3
QT117L

QUANTUM
Designed to Output raw Data over a Master-mode SPI Port
QDO H[KLELWV D ORJDULWKPLF UHVSRQVH )RU HYHU\ GRXEOLQJ RI &[ WKH VLJQDO GHFUHDVHV E\ DSSUR[LPDWHO\   7KH 63, RXWSXW YDOXH LV QRW FRPSHQVDWHG IRU GULIW 63, &ORFN 7KH 63, FORFN KDV  SRVLWLYHJRLQJ FORFN HGJHV WKDW VKRXOG EH XVHG WR FORFN WKH VHU
Datasheet
4
QT1081

Quantum
8-KEY QTOUCH SENSOR IC
as the older device but differs in the following ways: Š Rs resistors on each channel eliminated Š Up to 4x more sensitive for a given value of Cs Š Shorter burst lengths, less power for a given value of Cs Š ‘Burst B’ only mode for lower key counts
Datasheet
5
QT1080

QUANTUM
8 KEY QTOUCH SENSOR IC
which provide for reliable, trouble-free operation over the life of the product. Burst operation: The device operates in ‘burst mode’. Each key is acquired using a burst of charge-transfer sensing pulses whose count varies depending on the value of t
Datasheet
6
QT110H

QUANTUM
SENSOR ICs
One, toggle mode, permits on/off touch control for example for light switch replacement. Another makes the sensor output a pulse instead of a DC level, which allows the device to 'talk' over the power rail, permitting a simple 2-wire twisted-pair in
Datasheet
7
QT1101

QUANTUM
10 KEY QTOUCH SENSOR IC
which provide for reliable, trouble-free operation over the life of the product. Burst operation: The device operates in ‘burst mode’. Each key is acquired using a burst of charge-transfer sensing pulses whose count varies depending on the value of t
Datasheet
8
QT1106-ISG

QUANTUM
QWHEEL/QSLIDE/QTOUCH IC
which provide for reliable, trouble-free operation over the life of the product. In particular the QT1106 features advanced self-calibration, drift compensation, and fast thermal tracking. Unlike prior devices, the QT1106 can tolerate power supply fl
Datasheet
9
QT11x

QUANTUM
QT 11x Series Variations
s with QT110 The QT111 sensor is exactly the same in all respects to the QT110 with the following exceptions shown in bold (refer to Table 2-1 in the QT110 datasheet): Table 2-1 Output Mode Strap Options Tie Pin 3 to: DC Out DC Out Toggle Pulse Vdd
Datasheet
10
QT115

QUANTUM
QT 11x Series Variations
s with QT110 The QT111 sensor is exactly the same in all respects to the QT110 with the following exceptions shown in bold (refer to Table 2-1 in the QT110 datasheet): Table 2-1 Output Mode Strap Options Tie Pin 3 to: DC Out DC Out Toggle Pulse Vdd
Datasheet
11
QT140

QUANTUM
(QT140 / QT150) 4 AND 5 KEY QTOUCH SENSOR ICs
can lead to entirely new product concepts, adding high value to product designs. Each of the channels operates independently of the others, and each can be tuned for a unique sensitivity level by simply changing its sample capacitor value. The device
Datasheet
12
QT150

QUANTUM
(QT140 / QT150) 4 AND 5 KEY QTOUCH SENSOR ICs
can lead to entirely new product concepts, adding high value to product designs. Each of the channels operates independently of the others, and each can be tuned for a unique sensitivity level by simply changing its sample capacitor value. The device
Datasheet
13
QT1103

QUANTUM
10-KEY SENSOR IC
as the older device but differs in the following ways:
• Rs resistors on each channel eliminated
• Up to 4x more sensitive for a given value of Cs
• Shorter burst lengths, less power for a given value of Cs
• ‘Burst A and B’ only mode for up to eight
Datasheet
14
QT100

QUANTUM
CHARGE-TRANSFER IC
and is set to ~60s. This will vary slightly with Cs and if SYNC mode is used. As the internal timebase for Max On-duration is determined by the burst rate, the use of SYNC can cause dramatic changes in this parameter depending on the SYNC pulse spaci
Datasheet
15
QT110

QUANTUM
SENSOR ICs
One, toggle mode, permits on/off touch control for example for light switch replacement. Another makes the sensor output a pulse instead of a DC level, which allows the device to 'talk' over the power rail, permitting a simple 2-wire twisted-pair in
Datasheet
16
QT112

QUANTUM
QT 11x Series Variations
s with QT110 The QT111 sensor is exactly the same in all respects to the QT110 with the following exceptions shown in bold (refer to Table 2-1 in the QT110 datasheet): Table 2-1 Output Mode Strap Options Tie Pin 3 to: DC Out DC Out Toggle Pulse Vdd
Datasheet
17
QT114

QUANTUM
CHARGE-TRANSFER QLEVEL SENSOR IC
is the 'slosh filter', a detection integrator which averages detections over a rolling 15 second interval before activating or deactivating the OUT pins. This filter allows use of the QT114 with violently moving fluids, for example in a moving vehicl