No. | Partie # | Fabricant | Description | Fiche Technique |
---|---|---|---|---|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC 61000-4-2(ESD) : Air mode 20kV / Contact mode 18kV - IEC 61000-4-5(Surge) : 1.5A(tp=8/20 us) • Low capacitance CT = 0.3pF(Max) • Bi-directional, symmertrical working voltage up to : VRWM = • Extremel |
|
|
|
KEC |
Array Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 25kV - IEC61000-4-5(Surge) : 5A(tp=8/20Ǻs) hLow capacitance CT = 1.0pF(Max.) Any I/O pin to ground hUni-directional working voltage up to : VRWM = 5V hUltra |
|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 25kV - IEC61000-4-4(EFT) : 50A(5/50ns) - IEC61000-4-5(Surge) : 4A(tp=8/20us) • Low capacitance CT = 0.9pF(Max) • Uni-directional, symmertrical working voltage |
|
|
|
KEC |
Single Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 30kV - IEC61000-4-5(Surge) : 12A(tp=8/20Ǻs) hLow capacitance CT = 25pF(Max) hBi-directional, symmertrical working voltage up to : VRWM = 5V hSmall Size 1.0 |
|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 30kV - IEC61000-4-4(EFT) : 7A (tp=8/20us) • Low capacitance CT = 9pF(Max) • Bi-directional, symmertrical working voltage up to : VRWM = • Extremely small |
|
|
|
KEC |
Single Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 25kV / Contact mode 20kV - IEC61000-4-4(EFT) : 50A (5/50ns) - IEC61000-4-5(Surge) : 4A(tp=8/20Ǻs) hLow capacitance CT = 0.9pF(Max) hUni-directional, symmertrical working voltag |
|
|
|
KEC |
Single Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 30kV - IEC61000-4-4(EFT) : 80A(tp=5/50ns) - IEC61000-4-5(Surge) : 6A(tp=8/20Ǻs) hLow capacitance CT = 9pF(Max) hBi-directional, symmertrical working voltage |
|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 25kV - IEC61000-4-4(EFT) : 50A (5/50ns) - IEC61000-4-5(Surge) : 4A(tp=8/20us) • Low capacitance CT = 0.5pF(Max) • Bi-directional, symmertrical working voltage |
|
|
|
KEC |
Single Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 30kV - IEC61000-4-5(Surge) : 5A(tp=8/20Ǻs) hLow capacitance CT = 9pF(Max) hBi-directional, symmertrical working voltage up to : VRWM = 5V hExtremely small S |
|
|
|
KEC |
Array Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 25kV / Contact mode 20kV - IEC61000-4-5(Surge) : 4A(tp=8/20Ǻs) hLow capacitance CT = 0.6pF(Max) Any I/O pin to ground hUni-directional working voltage up to : VRWM = 5V hUltra s |
|
|
|
KEC |
Single Line TVS Diode Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 25kV/Contact mode 20kV - IEC61000-4-4(FET) : 50A(5/50ns) - IEC61000-4-5(Surge) : 4A(tp=8/20 s) Low capacitance CT = 0.5pF(Max) Bi-directional, symmertrical working voltage up to : |
|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 30kV - IEC61000-4-4(EFT) : 80A (tp=5/50ns) - IEC61000-4-5(Surge) : 6A(tp=8/20us) • Low capacitance CT = 9pF(Max) • Bi-directional, symmertrical working voltag |
|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 30kV - IEC61000-4-5(Surge) : 9A(tp=8/20 us) • Low capacitance CT = 0.9pF(Max) • Bi-directional, symmertrical working voltage up to : VRWM = 5V • Ultra small S |
|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 20kV / Contact mode 18kV - IEC61000-4-5(Surge) : 1.5A(tp=8/20 us) • Low capacitance CT = 0.3pF(Max) • Bi-directional, symmertrical working voltage up to : VRWM = 5V • Extremely s |
|
|
|
KEC |
Single Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 25kV / Contact mode 20kV - IEC61000-4-5(Surge) : 7A(tp=8/20Ǻs) hLow capacitance CT = 9pF(Max) hBi-directional, symmertrical working voltage up to : VRWM = 3.3V hExtremely small |
|
|
|
KEC |
Single Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 25kV / Contact mode 20kV - IEC61000-4-5(Surge) : 7A(tp=8/20Ǻs) hLow capacitance CT = 9pF(Max) hBi-directional, symmertrical working voltage up to : VRWM = 3.3V hExtremely small |
|
|
|
KEC |
Single Line TVS Diode hTransient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 30kV - IEC 61000-4-5(Surge) : 5A(tp=8/20Ǻs) hLow capacitance CT = 9pF(Max) hBi-directional, symmertrical working voltage up to : VRWM = 5V hExtremely small |
|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 20kV - IEC61000-4-4(EFT) : 50A (5/50ns) - IEC61000-4-5(Surge) : 4A (tp=8/20us) • Low capacitance CT = 0.5pF(Max) • Bi-directional, symmertrical working vo |
|
|
|
KEC |
Single Line TVS Diode • Transient protection for data lines to - IEC61000-4-2(ESD) : Air mode 30kV / Contact mode 30kV - IEC61000-4-5(Surge) : 12A(tp=8/20us) • Low capacitance CT = 25pF(Max) • Bi-directional, symmertrical working voltage up to : VRWM = 5V • Ultra small Si |
|