The TIOL111(x) family of transceivers implements the IO-Link interface for industrial bidirectional, point-topoint communication. When the device is connected to an IO-Link master through a three-wire interface, the master can initiate communication and exchange data with the remote node while the TIOL111(x) acts as a complete physical layer for the communic.
•1 7-V to 36-V Supply Voltage
• PNP, NPN or IO-Link Configurable Output
– IEC 61131-9 COM1, COM2 and COM3 Data Rate Support
• Low Residual Voltage of 1.75 V at 250 mA
• 50-mA to 350-mA Configurable Current Limit
• Tolerant to ±65-V Transients < 100 µs
• Reverse Polarity Protection of up to 60 V on L+,
CQ and L
• Integrated EMC Protection on L+ and CQ
– ±16 kV IEC 61000-4-2 ESD Contact Discharge
– ±4 kV IEC 61000-4-4 Electrical Fast Transient
– ±1.2 kV/500 Ω IEC 61000-4-5 Surge
• Fast Demagnetization of Inductive Loads up to 1.5 H
• Large Capacitive Load Driving Capability
• < 2-µA CQ Leakage Cu.
No. | Partie # | Fabricant | Description | Fiche Technique |
---|---|---|---|---|
1 | TIOL111 |
Texas Instruments |
IO-Link Transceivers | |
2 | TIOL1113 |
Texas Instruments |
IO-Link Transceivers | |
3 | TIOS101 |
Texas Instruments |
Digital Sensor Output Drivers | |
4 | TIOS1013 |
Texas Instruments |
Digital Sensor Output Drivers | |
5 | TIOS1015 |
Texas Instruments |
Digital Sensor Output Drivers | |
6 | TI-102 |
Premo |
PULSE TRANSFORMERS | |
7 | TI-103 |
Premo |
PULSE TRANSFORMERS | |
8 | TI-104 |
Premo |
PULSE TRANSFORMERS | |
9 | TI-105 |
Premo |
PULSE TRANSFORMERS | |
10 | TI-106 |
Premo |
PULSE TRANSFORMERS | |
11 | TI-107 |
Premo |
PULSE TRANSFORMERS | |
12 | TI-109 |
Premo |
PULSE TRANSFORMERS |