tfs380b.doc version 4.0 09.04.2001 VI TELEFILTER Filter specification TFS 380B 1/5 Measurement Condition Ambient Temperature: Input Power Level: Source impedance: Load impedance: Terminating impedances: input: output: 23 °C 0 dBm 50 Ω 50 Ω 810 Ω || -4.75 pF 990 Ω || -4.75 pF Characteristics Remark: Reference level for the relative attenuation arel is.
rtion Loss (Reference level) Nominal Frequency 1,5 dB - Bandwidth Relative Attenuation fN ± 5 fN ± 5,8 fN ± 6,3 fN ± 6,6 fN ± 10,0 MHz ... fN ± 5,8 MHz ... fN ± 6,3 MHz ... fN ± 6,6 MHz ... fN ± 10 MHz ... fN ± 100,0 ae = amin typ. Value max. Limit 20,5 dB fN BW min. 380,0 MHz 8,0 MHz arel MHz MHz MHz MHz MHz min. min. min. min. min. 3 10 20 30 40 dB dB dB dB dB Pass Band Ripple fN ± 4,0 MHz Group delay ripple fN ± 4,0 MHz Operating Temperature Range ϕ - max. 1,5 dB - max. 100 ns - 0 °C ... + 70 °C Generated: Checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW.
No. | Partie # | Fabricant | Description | Fiche Technique |
---|---|---|---|---|
1 | TFS380A |
ETC |
TELEFILTER | |
2 | TFS380C |
ETC |
VI TELEFILTER Filter specification | |
3 | TFS380G |
ETC |
TELEFILTER | |
4 | TFS35A |
Vectron International |
Filter specification | |
5 | TFS35B |
Vectron International |
Filter specification | |
6 | TFS360A |
ETC |
TELEFILTER Filter Specification | |
7 | TFS360B |
Vectron International |
Filter | |
8 | TFS-S |
Vishay |
Thin Film Nickel Temperature Sensors | |
9 | TFS-W |
Vishay |
Thin Film Nickel Temperature Sensors | |
10 | TFS110D |
Vectron International |
Filter Specification | |
11 | TFS110K1 |
ETC |
Filter | |
12 | TFS110K2 |
ETC |
TELEFILTER Filter specification |