Subminiature Intermediate Power Relay SRU ❚ 10A switching capabilities ❚ SPNO & SPCO configuration ❚ Subminiature, standard PC layout ❚ Sealed Construction ❚ Creepage distance: 8mm (both for CO & NO) ❚ Clearance distance: NO type 4.5mm, CO type 4mm Options and ordering codes SRU Sensitivity Standard Sensitive (SPNO) H - 1A - S L - 12VDC Coil Voltage .
switching current 10A 3A Max. switching power 1250VA/150W 750VA/90W Max. switching voltage 277VAC/30VDC Mechanical life 1x107 OPS Electrical life 1x105 OPS Pick-up Voltage VDC 2.25 3.75 4.50 6.75 9.00 13.5 18.0 36.0 Characteristics Initial Insulation Resistance 1000MΩ @ 500VDC Between coil & contact 4000VAC 1min. Dielectric Strength Between open contacts 1000VAC 1min. Operate time (at nomi. Volt) Max. 8ms Release time (at nomi. Volt) Max. 5ms Ambient temperature -40˚C to +70˚C Humidity 35% to 95% Functional 100m/s2 Shock resistance Destructive 1000m/s2 Vibration resistance 1.6mm, 10 to 55Hz.
No. | Partie # | Fabricant | Description | Fiche Technique |
---|---|---|---|---|
1 | SRU-12VDC-F-D-A |
SONGLE |
RELAY | |
2 | SRU-12VDC-F-D-B |
SONGLE |
RELAY | |
3 | SRU-12VDC-F-D-C |
SONGLE |
RELAY | |
4 | SRU-12VDC-F-L-A |
SONGLE |
RELAY | |
5 | SRU-12VDC-F-L-B |
SONGLE |
RELAY | |
6 | SRU-12VDC-F-L-C |
SONGLE |
RELAY | |
7 | SRU-12VDC-S-D-A |
SONGLE |
RELAY | |
8 | SRU-12VDC-S-D-B |
SONGLE |
RELAY | |
9 | SRU-12VDC-S-D-C |
SONGLE |
RELAY | |
10 | SRU-12VDC-S-L-A |
SONGLE |
RELAY | |
11 | SRU-12VDC-S-L-B |
SONGLE |
RELAY | |
12 | SRU-12VDC-S-L-C |
SONGLE |
RELAY |