1 CTLD DO control pin 2 CTLC CO control pin 3 CO Output pin for overcharge detection 4 DO Output pin for overdischarge detection 5 SEL1 6 SEL2 Switching pins for 3-serial to 5-serial cell*1 7 CDT Capacitor connection pin for delay for overdischarge detection voltage 8 CCT Capacitor connection pin for delay for overcharge detection voltage 9 VS.
• High-accuracy voltage detection function for each cell
Overcharge detection voltage n (n = 1 to 5)
3.5 V to 4.4 V (50 mV step)
Overcharge release voltage n (n = 1 to 5)
Accuracy ±20 mV (Ta = +25°C), ±30 mV (Ta = 0°C to +60°C)
3.3 V to 4.4 V
*1
Accuracy ±50 mV
Overdischarge detection voltage n (n = 1 to 5) Overdischarge release voltage n (n = 1 to 5)
2.0 V to 3.2 V (100 mV step) 2.1 V to 3.4 V
*2
Accuracy ±80 mV Accuracy ±100 mV
• Overcharge detection delay time and overdischarge detection delay time can be set by external capacitor.
• Switchable between 3-serial to 5-serial cell by.
1 CTLD DO control pin 2 CTLC CO control pin 3 CO Output pin for overcharge detection 4 DO Outpu.
No. | Partie # | Fabricant | Description | Fiche Technique |
---|---|---|---|---|
1 | S-8225B |
ABLIC |
BATTERY MONITORING | |
2 | S-8225B |
Seiko Instruments |
BATTERY MONITORING IC | |
3 | S-8223A |
ABLIC |
Battery Protection | |
4 | S-8223B |
ABLIC |
Battery Protection | |
5 | S-8223C |
ABLIC |
Battery Protection | |
6 | S-8223D |
ABLIC |
Battery Protection | |
7 | S-8224A |
ABLIC |
Battery Protection | |
8 | S-8224B |
ABLIC |
Battery Protection | |
9 | S-8229 |
ABLIC |
BATTERY MONITORING | |
10 | S-8229A |
ABLIC |
BATTERY MONITORING | |
11 | S-8200A |
ABLIC |
Battery Protection | |
12 | S-8200A |
Seiko Instruments |
BATTERY PROTECTION IC |