section explains how to optimize the configuration of the QPO-1 for the voltage source used. The headroom voltage is the difference between the input and the output of the QPO-1 and is set by the selection of resistor RHR. Calculate RHR as shown. RHR = (QPOOUT / VHR ) x 2.5k (see Table 1 for example values) (2) RSS resistor sets the correction current requ.
• >20dB PARD attenuation from 50Hz to 500kHz
• Supports point of load regulation
• Peak ripple detector optimizes performance automatically
• Significantly improves load transient response
• Efficiency up to 98%
• User selectable performance optimization
• 3-30Vdc operating range
• 10A rating
TM
Output Ripple Attenuation SiP
Patents Pending
Shown actual size: 1.0 x 1.0 x 0.2 in 25 x 25 x 5 mm
Absolute Maximum Ratings Product Highlights
Picor’s QPO-1 output ripple attenuator System-in-a-Package (SiP) provides active filtering to achieve greater than 20 dB attenuation of periodic and random .