The INA193A current shunt monitors with voltage output can sense drops across shunts at common-mode voltages from –16 V to 80 V, independent of the INA19x supply voltage. They are available with three output voltage scales: 20 V/V, 50 V/V, and 100 V/V. The 500-kHz bandwidth simplifies use in current control loops. The INA193A operates from a single 2.7-V to .
1
• Wide Common-Mode Voltage:
–16 V to 80 V
• Low Error: 3.0% Over Temp (Max)
• Bandwidth: Up to 500 kHz
• Three Transfer Functions Available: 20 V/V,
50 V/V, and 100 V/V
• Complete Current Sense Solution
APPLICATIONS
• Welding Equipment
• Notebook Computers
• Cell Phones
• Telecom Equipment
• Automotive
• Power Management
• Battery Chargers
SUPPORTS DEFENSE, AEROSPACE, AND MEDICAL APPLICATIONS
• Controlled Baseline
• One Assembly/Test Site
• One Fabrication Site
• Available in Military (
–55°C/125°C)
Temperature Range (1)
• Extended Product Life Cycle
• Extended Product-Change Notification
• .
No. | Partie # | Fabricant | Description | Fiche Technique |
---|---|---|---|---|
1 | INA193A-Q1 |
Texas Instruments |
Current Shunt Monitor | |
2 | INA193 |
Burr-Brown Corporation |
CURRENT SHUNT MONITOR | |
3 | INA193 |
Texas Instruments |
Current Shunt Monitor | |
4 | INA190 |
Texas Instruments |
Precision Current-Sense Amplifier | |
5 | INA190-Q1 |
Texas Instruments |
Ultra-Precise Current Sense Amplifier | |
6 | INA191 |
Texas Instruments |
Ultra-Precise Current Sense Amplifier | |
7 | INA194 |
Burr-Brown Corporation |
CURRENT SHUNT MONITOR | |
8 | INA194 |
Texas Instruments |
Current Shunt Monitor | |
9 | INA194A-Q1 |
Texas Instruments |
Current Shunt Monitor | |
10 | INA195 |
Burr-Brown Corporation |
CURRENT SHUNT MONITOR | |
11 | INA195 |
Texas Instruments |
Current Shunt Monitor | |
12 | INA195A-Q1 |
Texas Instruments |
Current Shunt Monitor |