PD-97987 GHP10006S 100V Input, Single Output GHP Features Total Dose > 100 kRads(Si) SEE Hardened to LET up to 82 MeV·cm2/mg Low Weight < 110 grams Low Input & Output Noise Magnetically Coupled Feedback 65V to 110V DC Input Range Up to 96W Output Power 6V Single Output High Efficiency to 83% -55°C to +125°C Operating Temperature Range .
Total Dose > 100 kRads(Si)
SEE Hardened to LET up to 82 MeV
·cm2/mg
Low Weight < 110 grams
Low Input & Output Noise
Magnetically Coupled Feedback
65V to 110V DC Input Range
Up to 96W Output Power
6V Single Output
High Efficiency to 83%
-55°C to +125°C Operating Temperature Range
100M @ 500VDC Isolation
Under-Voltage Lockout
Short Circuit and Overload Protection
Adjustable Output with an External Resistor
Remote Sense on Single Output Models
Synchronization Input and Output
External Inhibit
> 3.3 Million Hours MTBF
Applications
Geostationary Earth Orbit Sat.
No. | Partie # | Fabricant | Description | Fiche Technique |
---|---|---|---|---|
1 | GHP12003R3S |
Micross |
Radiation Hardened DC-DC Converter | |
2 | GHP12005D |
Micross |
Radiation Hardened DC-DC Converter | |
3 | GHP12005S |
Micross |
Radiation Hardened DC-DC Converter | |
4 | GHP12012D |
Micross |
Radiation Hardened DC-DC Converter | |
5 | GHP12012S |
Micross |
Radiation Hardened DC-DC Converter | |
6 | GHP12015D |
Micross |
Radiation Hardened DC-DC Converter | |
7 | GHP12015S |
Micross |
Radiation Hardened DC-DC Converter | |
8 | GHP2805D |
Micross |
HYBRID-HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTER | |
9 | GHP2805S |
Micross |
HYBRID-HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTER | |
10 | GHP2812D |
Micross |
HYBRID-HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTER | |
11 | GHP2812S |
Micross |
HYBRID-HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTER | |
12 | GHP2815D |
Micross |
HYBRID-HIGH RELIABILITY RADIATION HARDENED DC-DC CONVERTER |