PE-51686 |
Part Number | PE-51686 |
Manufacturer | Pulse |
Description | THT CURRENT SENSE TRANSFORMERS & INDUCTORS DVE VDE Approved Designed for switching power supply applications Transformer meets IEC950 insulation requirements Frequency range from 20kHz to 200kHz Ele... |
Features |
product of a square pulse of current in amps, times the current pulse width in microseconds. 3. Maximum operating temperature 105°C (ambient plus rise).
Secondary Inductance
MH (MIN)
5.0
20.0
80.0
5.0
20.0
80.0 180.0
Secondary Inductance Test Voltage (15.75 KHz)
0.5
1.0
2.0
0.5
1.0
2.0 3.0
RS (Ω MAX)
0.7 1.40 4.50 0.7 1.40 4.50 11.0
RT (Ω NOM)
50 100 200 50 100 200 300
Primary Unipolar Amp µ Sec. Rating (MAX)
150
300
600
150
300
600 900
Primary Bipolar Amp µ Sec. Rating (MAX)
300
600
1200
300
600
1200 1800
4. When terminated with rated terminating resistance, the inductor scale factor ... |