ME4-H2 Winsen Hydrogen Gas Sensor Datasheet, en stock, prix

logo
Recherchez avec le numéro de pièce ainsi que le fabricant ou la description

ME4-H2

Winsen
ME4-H2
ME4-H2 ME4-H2
zoom Click to view a larger image
Part Number ME4-H2
Manufacturer Winsen
Description of sensor characters 6 5 Fig2: ME4-H2 test circuit 12 10 Output signal/μA 48 36 24 12 0 0 100 200 300 Time/s Fig3.Responce and Resume 180% 0 0 200 400 600 800 1000 Concentration/ppm Fig4.Linea...
Features Low power consumption, high precision, high sensitivity, wide linear range, good anti-interference ability, excellent repeatability and stability. Main applications It is used for hydrogen detection in industrial occasion and environmental protection field. Technical Parameters Stable1. Detection Gas Detection Range Max range Sensitivity Resolution Response Time(T90) Bias Voltage Load Resistance Repeatability Stability(/month) Output Linearity Zero drift(-20℃~40℃) Temperature range Humidity range Pressure range Lifespan hydrogen(H2) 0~1000ppm 2000ppm (0.03±0.01)µA/ppm 1ppm ≤30S 0mV 10Ω(recom...

Document Datasheet ME4-H2 Data Sheet
PDF 420.08KB
Distributor Stock Price Buy

Similar Datasheet

No. Parte # Fabricante Descripción Hoja de Datos
1 ME4-NH3
Winsen
Ammonia Gas Sensor Datasheet
2 ME4-SO2
Winsen
Electrochemical Sulfur Dioxide Sensor Datasheet
3 ME401C
Microne
DC-DC Converter Datasheet
4 ME4054
Microne
Standalone Linear Li-Ion Battery Charger Datasheet
5 ME4056
ChipSourceTek
1A Lithium Ion Battery Linear Charger Datasheet
More datasheet from Winsen
Depuis 2018 :: D4U Semiconductor :: (Politique de confidentialité et contact