DataSheet.in

6EDL4 डेटा पत्रक PDF( Datasheet डाउनलोड )


डेटा पत्रक - Power Entry Module - Tyco

भाग संख्या 6EDL4
समारोह Power Entry Module
मैन्युफैक्चरर्स Tyco 
लोगो Tyco लोगो 
पूर्व दर्शन
1 Page
		
<?=6EDL4?> डेटा पत्रक पीडीएफ

6EDL4 pdf
CORCOM Product Guide
L Series
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
Specifications
Electrical Schematics
DL Models (with switch)
Neutral
Ground
Hot
Note 1
Note 2
H On/Off
21
(1) (1a)
(2) (2a)
43
Cutomer
Transformer
Primaries
Device
G
DL Models (with 4-voltage selection)
Hot
Ground
Neutral
Note 1 G
120V
100V
Note 2 A
On/Off
B
C
D
E
F
H
220V
240V
Cutomer
Transformer
Primaries
AA
20V
BB
100V
CC
DD
E E 120V
FF
HL Models (with switch)
Neutral
Ground
Hot
Note 1
Note 2
H On/Off
21
(1) (1a)
(2) (2a)
43
G
Customer
Transformer
Primaries
Device
HL Models (with 4-voltage selection)
Hot
Ground
Neutral
Note 1 G
120V
100V
Note 2 A
On/Off
B
C
D
E
F
H
220V
240V
Customer
Transformer
Primaries
AA
20V
BB
100V
CC
DD
E E 120V
FF
Maximum leakage current, each line-to-ground:
@120 VAC 60 Hz:
@250 VAC 50 Hz:
EDL EHL
Models Models
0.25 mA 2 µA
0.50 mA 5 µA
Hipot rating (one minute):
line-to-ground
line-to-line
1500
1450
1500
1450
Operating frequency:
Operating voltages:
1S & 1SC Suffix (fixed):
4 & 4C Suffix (selectable):
Rated current:
50/60 Hz
250 VAC Max.
100, 120, 220, 240 VAC
2EDL & 2EHL
4EDL & 4EHL
6EL, 6EDL & 6EHL
2A
4A
6A
Switch:
Double-insulated, rated
for 10,000 operations at full
load. 51 Amp inrush capability.
Fuse (not included):
Accepts one .25" x 1.25" fuse
or two 5 x 20 mm fuses
Terminals:
110 [2.79] except for switch
.187 [4.8] for switch
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating .05 .15 1
5
EDL Models
2A 6
4A 2
6A 1
EHL Models
06A 3
14 24 40
8 18 32
6 17 31
8 15 18
10
45
38
37
18
30
50
45
45
18
Line-to-line in 50 ohm circuit
Current
Rating .05
EDL Models
2A 7
4A 6
6A 6
EHL Models
06A 4
Frequency-MHz
.5 1 3
16 21 23
14 18 23
15 20 25
14 20 28
5
37
26
24
32
10 30
47 50
45 47
45 50
38 42
Note 1: Provision for dual European style fusing.
Note 2: On/Off switch present only with "S" suffix.
Resistor location for reference only.
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
119
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheetlist.com/

विन्यास 4 पेज
डाउनलोड[ 6EDL4 Datasheet.PDF ]


शेयर लिंक


अनुशंसा डेटापत्रक

भाग संख्याविवरणविनिर्माण
6EDL04I06NTHigh voltage gate driver ICInfineon
Infineon
6EDL04I06PTHigh voltage gate driver ICInfineon
Infineon


भाग संख्याविवरणविनिर्माण
30L120CTSchottky RectifierPFC Device
PFC Device
AT28C010-12DKSpace 1-MBit (128K x 8) Paged Parallel EEPROMATMEL
ATMEL
B20NM50FDN-CHANNEL POWER MOSFETSTMicroelectronics
STMicroelectronics
D8442SD844SavantIC
SavantIC
FAE391-A20AM/FM Automotive Electronic TunerMitsumi
Mitsumi


Index : 0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z



www.DataSheet.in    |   2017   |  संपर्क   |   खोज     |   English