DataSheet.in

LC010B डेटा पत्रक PDF( Datasheet डाउनलोड )


डेटा पत्रक - Power Modules - Tyco Electronics

भाग संख्या LC010B
समारोह Power Modules
मैन्युफैक्चरर्स Tyco Electronics 
लोगो Tyco Electronics लोगो 
पूर्व दर्शन
1 Page
		
<?=LC010B?> डेटा पत्रक पीडीएफ

LC010B pdf
LC/LW010- and LC/LW015-Series Power Modules:
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W
Absolute Maximum Ratings
Data Sheet
August 1998
www.DataSheet4U.com
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Parameter
Input Voltage:
Continuous
Transient (100 ms)
Operating Case Temperature
(See Derating Curves, Figures 4345.)
Storage Temperature
I/O Isolation
Device
LC
LW
LW
All
All
All
Symbol
VI
VI
VI, trans
TC
Tstg
Min
0
0
0
40
55
Typ Max Unit
50 Vdc
80 Vdc
100
V
105* °C
125 °C
1500
Vdc
* Maximum case temperature varies based on power dissipation. See derating curves, Figures 4345, for details.
Electrical Specifications
Table 1. Input Specifications
Parameter
Device Symbol Min
Typ
Max
Unit
Operating Input Voltage
Maximum Input Current
(VI = 0 to VI, max; IO = IO, max; see Figures
14.)
Inrush Transient
Input Reflected-ripple Current
(5 Hz to 20 MHz; 12 µH source imped-
ance; TA = 25 °C; see Figure 33.)
Input Ripple Rejection (100 Hz120 Hz)
LC
LW
LC
LW
All
All
All
VI
VI
II, max
II, max
I2t
II
18
36
24 36 Vdc
48 75 Vdc
1.6
A
800 mA
0.2 A2s
5 mAp-p
45 dB
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturers data for further information.
2 Tyco Electronics Corp.

विन्यास 24 पेज
डाउनलोड[ LC010B Datasheet.PDF ]


शेयर लिंक


अनुशंसा डेटापत्रक

भाग संख्याविवरणविनिर्माण
LC010APower ModulesTyco Electronics
Tyco Electronics
LC010BPower ModulesTyco Electronics
Tyco Electronics


भाग संख्याविवरणविनिर्माण
30L120CTSchottky RectifierPFC Device
PFC Device
AT28C010-12DKSpace 1-MBit (128K x 8) Paged Parallel EEPROMATMEL
ATMEL
B20NM50FDN-CHANNEL POWER MOSFETSTMicroelectronics
STMicroelectronics
D8442SD844SavantIC
SavantIC
FAE391-A20AM/FM Automotive Electronic TunerMitsumi
Mitsumi


Index : 0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z



www.DataSheet.in    |   2017   |  संपर्क   |   खोज     |   English